Use this simple atomic physics calculator to calculate equivalent dose absorbed by tissue for radiological protection online.

Radiation weighting factors WR (formerly termed Q factor) according to ICRP report 103
RadiationEnergyWR (formerly Q)
protons, charged pions2
alpha particles,Nuclear fission products,heavy nuclei20
x-rays, gamma rays,beta particles, muons1
neutrons< 1 MeV2.5 + 18.2e−[ln(E)]²/6
1 MeV - 50 MeV5.0 + 17.0e−[ln(2*E)]²/6
>50 MeV2.5 + 3.25e−[ln(0.04*E)]²/6

Formula:

HT = D × Q

where,
HT - is the equivalent dose absorbed by tissue T
D - is the absorbed dose in tissue T by radiation type R
WR or D - is the radiation weighting factor defined by ICRP regulation